Mississauga, ON
Canadian privately owned high voltage electrical service company since 1953. Provides associated services priority in Southern Ontario but have worked world wide.
3354 Mavis Rd.
Mississauga, ON L5C 1T8
CA
3354 Mavis Rd.
Mississauga, ON L5C 1T8
CA
Legal Name: G. T. Wood Co. Ltd.
Number of Employees: 25
CA
Specializing high voltage electrical maintenance and repairs. Installation and refurbishing of substations. Provide engineering services.
Title: Vice President
Area of Responsibility: Management Executive
Phone: Show phone
Fax: Show fax
Email: Show email
Title: Treasurer
Area of Responsibility: Finance/Accounting
Phone: Show phone
Fax: Show fax
Email: Show email
Title: President
Area of Responsibility: Management Executive
Phone: Show phone
Fax: Show fax
Email: Show email
Retrofit programs can be established for various reasons, such as:
Aging equipment; Equipment failure; Damaged equipment; Relocation of equipment; System voltage change; System design modification;
Electrical code requirements
Our Engineering department will review the requirements and make the necessary recommendations.
Our Operations department will provide the technical expertise to effect the required retrofit program using factory replacement components.
The following outlines the types of equipment addressed by a retrofit program:
Interlock systems; High voltage switchgear; Analogue relays;
Mechanical tripping devices on circuit breakers; Ground fault protection; Power capacitors; Lightning arrestors
A Sales Representative is available to review your system requirements upon request.
Whether you are considering the installation of new electrical systems, or simply upgrading an existing application, G. T. Wood engineers will design each of the above services to meet your specific requirements.
flexible braid, flexible braided connectors, insulators, lightning arrestors and high and low voltage bushings
In the event of an emergency of a planned situation, two mobile high voltage substations are available to rent. These units can be modified for transformation at 44, 27.6, 13.8 KV. The size of the transformers and the low voltage board can also be modified to suit the requirements of your specific situation.
Types of Braid Used:
Standard Thickness:
600, 900 and 1200A - 1/4' 6.4 mm); 1600 and 2000 A - 3/8' (9.5mm)
Non-Standard Extras
pattern; Hole size; Thickness; Insulation; Plating.
G. T. Wood flex connectors reflect standard ratings, however, non-standard sizes can also be produced. Please provide a sketch to G. T. Wood for quotation.
liquid
(Standard 5 part ASTM, Dissolved gas analysis, furan, Inhibitor, Power factor, PPM/Water, PPM/PCB).
components
After each maintenance inspection, a complete report will be issued to you outlining the equipment serviced, any defects found and any recommendations made for repairs. A copy of the report will be retained by G. T. Wood as part of your client file.
Regularly scheduled high-voltage preventative maintenance programs not only reduce operational costs - they're also vital in reducing the risk of unexpected electrical system failures.
In-House Testing Capabilities
Insulation resistance; DC resistance; Power factor; Dissipation power factor; Induced high voltage; Core loss; Copper loss;
Ratio; Hi Pot.
In-Shop Repair Capabilities:
coils)
G. T. Wood technicians can also carry out the above repairs on-site, if necessary and feasible. When required, transformers can be tested in accordance with CSA standards.