Varennes, QC
Sanexen Environmental Services Inc. has been offering technological solutions in the field of environmental services since 1985. Specializing in PCB waste management and in site remediation, Sanexen also offers a range of water treatment and decontamination services and carries out toxicological risk assessments. Sanexen also carries out the rehabilitation of underground lines using trenchless technologies.
Sanexen's staff is made up of 40 qualified and competent professionals, including engineers, scientists and technicians. Several proprietary technologies are available and Sanexen emphasize the development of new methods geared at cost effective environmental solutions to customer needs. The main technologies available are: Decontaksolv, for decontamination of electrical equipment, PCBD, for regeneration of mineral oils, Ultrasorption, for water treatment and Aqua-Pipe, for the structural rehabilitation of potable water lines.
32-1471 Lionel-Boulet Blvd.
Varennes, QC J3X 1P7
CA
32-1471 Lionel-Boulet Blvd.
Varennes, QC J3X 1P7
CA
Legal Name: Sanexen Services Environnementaux Inc.
Number of Employees: 60
CA
See following sections
Title: President
Area of Responsibility: Management Executive
Phone: Show phone
Fax: Show fax
Email: Show email
Title: Vice President
Area of Responsibility: Research/Development/Engineering
Phone: Show phone
Fax: Show fax
Email: Show email
Title: Director
Area of Responsibility: Export Sales & Marketing
Phone: Show phone
Fax: Show fax
Email: Show email
Dehalogenation and elimination of PCBs present in mineral oil and regeneration of dielectric properties of transformer oil. Mobile units work on site.
Process and service for the decontamination of PCB electrical equipment, allowing the removal of PCBs and the recovery of valuable metals. Used commercially in Canada for the past 12 years.
Studies on the effects of contaminants on human health, and the environment assessment of the acceptability of various management scenarios for contaminated sites. Software allowing the assessment of toxicological and ecotoxicological risks.
Implementation of corrective measures to remediate / clean properties and buildings that are contaminated. Treatment of soil and water, disposal of waste, cleaning of surfaces and of materials.
Cured-in-place piping for the trenchless structural rehabilitation of watermains
The Decontaksolv (TM) process used by Sanexen Services Environnementaux Inc. uses the properties of a reusable liquid to extract the PCBs contained in transformer carcasses and other electrical equipment. The system includes a closed area for the dismantling of the electrical equipment, an air ventilation and filtration system, an autoclave, a distiller, heat exchangers, a thermal unit and a drying unit for the processing of liquid waste after the extraction process.
First, the electrical equipment is segregated and the metal housings are then decontaminated in the autoclave. Smaller components are introduced into the autoclave through the use of baskets where they are washed with the extraction liquid. After the extraction cycle, a hot air stream circulates in the autoclave in a closed circuit in order to dry the material and to process the liquid waste. The treated material is then analyzed to ensure conformity and is then sent to a recycling facility. The process can be performed on site or in our fixed facility in Montral Qubec.
541620, 541330
Brazil, Japan
Russian Federation, United States