Eaton Electrical Canadian Operations
Eaton Electrical, Cutler-Hammer Brand:
Our manufacturing base in Canada consists of five facilities
located in Ontario, Alberta and British Columbia. Our sales and
field services offices are represented in each major city across
Canada.
Products:
Electrical control and industrial control products
Power distribution components:
moulded case circuit breakers, power moulded case circuit
breakers, vacuum circuit breakers 600v to 27 kv,
microprocessor-based protection relays, integrated monitoring,
protection and control communications (IMPACC), fuses, high
voltage.
Industrial controls:
motors starters LV/HV, motor control centres, control counters
and sensors, adjustable frequency/voltage drives, pushbuttons,
limit switches relays, vacuum contactors LV/HV, programmable
logic controllers.
A world mandate for fire pump controller, semi conductor power
panels, oil well pump and irrigation pump controllers has
been assigned to Cutler-Hammer Canada.
Power distribution equipment:
distribution switchboards, metalclad switchgear, load
interrupter switchgear, automatic transfer switches, unit
substations, panelboards/loadcentres, metercentres, safety
switches, retrofit packages.
From the foregoing listing of products, it is seen we are
focussed on commercial, institutional and industrial segments.
The worldwide installed base of our equipment has produced
and extensive network of distributors.
The design standards of our products are CSA, EEMAC, UL and
NEMA. In support of our products is a dedicated staff of sales
engineers, and application engineers to assist our customers in
application, project design, specification writing and systems
analysis.
Company Details
Year Established:
1910
Total Sales ($CDN):
$1,000,000 - $5,000,000
Number of Employees:
650
Company Information
Rick Hampton
Title:
Manager
Area of Responsibility:
Domestic Sales & Marketing
Telephone:
(905) 631-4103
Fax:
(905) 631-4248
Email:
Click Here
Steve Boccadoro
Title:
General Manager
Area of Responsibility:
Management Executive
Telephone:
(905) 631-4243
Fax:
(905) 631-4148
Email:
Click Here
Brian Savaria
Title:
Manager
Area of Responsibility:
Government Relations
Telephone:
(905) 631-4148
Fax:
(905) 631-4128
Email:
Click Here
Ann Sykes
Title:
Engineer
Area of Responsibility:
Domestic Sales & Marketing
Telephone:
(905) 631-4219
Fax:
(905) 631-4286
Email:
Click Here
Products
Process & Multi-function Control Mach/App Nes
Starters, Electric Motor
Control Equipment, Electrical, Ind Pts Of Nes
Control Equipment, Electrical, Industrial Nes
Relays, Electric Power, Protective
Switches, Industrial Control Type
Measuring & Meas/Controlling Inst Parts Nes
Fire Pump Controller
Fire Pump Controller for control of electric or diesel driven
fire protection pump systems - sprinklers. Electric controllers
either direct-on-line or reduced voltage, with transfer switch
option. HP size from 15 -400HP at 600 volts.
A world mandate for this product has been assigned to
Cutler-Hammer Canada .
Semiconductor Power Panels
Semiconductor Power Panels
Semiconductor equipment manufacturers use specialized power
panels controlling the process of semiconductor 'CHIP'
production.
A world mandate for this product, has been assigned to
Cutler-Hammer Canada.
Oil Well Pump Controllers
Oil Well pumping controllers are weatherproof panels operating
3 phase or 1 phase motors driving donkey pump equipment.
A world mandate for this product has been assigned to
Cutler-Hammer Canada.
Irrigation Pump Controllers
Irrigation Pump Controllers
Controllers for use with radial or in-line irrigation pump
systems.
A world mandate for this product has been assigned to
Cutler-Hammer Canada.
Electrical Power/Control/Automation
Electrical products include: Moulded case circuit breakers, power
circuit breakers, Motor starters, Motor Control Centers,
Switchboards, panelboards and residential panelboards, power
communications systems (IMPACCC) and automation products.
Adjustable Speed Drives
Adjustable speed drives (frequency control), rated 600 volts max.
HP range 0.75 to 1100 hp. Drives conform to CSA, UL, cUL,and CE
approval standards. Control integrated via control panel or PC.
Drive applications: hoists, pumps, fans.
Environmental Products And Services
Energy Monitoring System.
Tenants have the option to decrease consumption if they monitor energy usage. By reducing their consumption, peak demand charges (often a substantial portion of a building's electric bill) will be lowered, thus making the building more attractive to prospective tenants.
Decreases in energy consumption are also important in manufacturing facility departments or 'lines'. Many manufacturing companies are now placing the responsibility for energy budgeting at the line foreman level... and this includes calculating costs just the same as for labour, materials, and other direct expenses.
With Cutler-Hammer's Integrated Monitoring Protection and Coordination Communication (IMPACC) system, energy costs can be allocated by department, process or area of a facility to increase accountability. Additional information can be used to shed non-critical loads or reschedule loads to reduce peak demand charges. Individual motors and loads can be tracked to improve efficiency and decrease downtime. Historical trending functions can be used to develop daily or seasonal load profiles. Cutler-Hammer's IMPACC system can give feedback on where energy can be reduced, as well as results of energy conservation programs.
Cutler-Hammer can provide energy metering devices from the utility incoming line down to a 15 A breaker or fractional HP motor with the following products:
Digitrip OPTIM Trip Unit: Trip unit for Series C frame, SPB and DS circuit breakers (70 A through 5,000 A) which monitors power and energy.
Digitrip RMS 810: Trip unit for Series C R-Frame, SPB and DS breakers which monitors current; power; and energy (watts, peak demand, and watt-hours). Digitrip RMS 910: Trip unit for Series C R-Frame, SPB and DS breakers which monitors current; voltage; power (watts, peak demand); energy; power factor; and total harmonic distortion.
IQ Analyzer: Premier power quality meter which includes: current; voltage; power (watts, vars, and VA); energy; frequency; demand; power factor; %THD current; %THD voltage; K Factor; CBEMA derating factor; crest factor; and configurable I/O: 3 discrete inputs, 4 relay outputs, 1 analog input, 3 analog outputs.
IQ Central Energy Display: Monitors and displays energy information (watts, peak demand, and watt-hours) from up to 58 IQ Energy Sentinels and IQ DataPlus II devices. IQ Data Plus II: Digital power meter which includes: current; voltage; power (watts and vars); energy; frequency; demand; power factor; and voltage protection. IQ Energy Sentinel: Submetering device that mounts on the load end of a Series C Circuit Breaker and monitors both power and energy (watts, peak demand, and watt-hours). Universal IQ Energy Sentinel: Submetering device that can be either DIN rail or panel- mounted that monitors both power and energy (watts, peak demand, and watt-hours).
These devices can function as stand alone units, be included in an IMPACC system, or even be incorporated into existing building management or distributed control systems.
Services